Basic Guideline: the fan will be controlled by pit Temp. first. There are 4 pit temperature stages.
Whenever the meat temperature reachs to P1, the Meat temperature will take over control of fan.
There are 4 meat temperature stages.
When meat temperature controlls the fan, the pit temperature is limited under P5, this way it avoids over burning meat
Summary:
Working source DC 12V, 2A
probes:PT100, temperature range 0-200C
Temperature range -50 to 400C for controller,
Output: PID 0 to 12V, or simple on/off
Control Panel:
NO Letter Description
1 PV1 Pit Temp Measured Data
2 SV1 Pit Temp Set Data
3 PV2 Meat Temp Measured Data
4 SV2 Meat Temp Set Data
5 BATT Low Battery Voltage
6 OUT Output Indicate
7 ALM1/ALM2 High/Low temperature Alarm
8 AUTO Automatic Mode
9 MAN Manual Mode
10 SET1 to set Pit Temp
11 < /BEEP move left or alarm sound On/Off
12 - reduce
13 + increase
14 SET2 To set Meat Temp
15 AT/M change between automatic/manual
Setting temp.
Press "SET1", PV1 window will show "SC ,TC,AL,AH,", press "< +-" to set data in SV Window.
Press "SET2" to save above changes
Setting temp.
Press "SET2", PV2 window will show "P1,T1,P2,T2,P3,t3,P4,T4,P5", press "< +-" to set data in SV Window.
Press "SET1" to save above changes
Setting Parameter£º
Pres "SET1" and hold for 3 seconds till appearing " F-C", press "SET1", it will show Hdc. Set data accordingly,. Press "SET2" to save
Setting Maximum Fan Speed (HDC) in %.
Setting Mimimum Fan Speed(UDC)
Press "SET1" for 9 seconds, till appearing "P", press "SET1" a few times will appear "Udc", press "+" or "-" till motor starts to run, press "SET2" to save
P Default 30
I Default 240
D Default 60
Udc Minimum Speed of blower Default 0, you must set Udc to avoid burning fan
F-C 0=C 1=F Default 0
HdC Maximum Speed of Blower Default 100%
Phase I
SC1 Pit Temps
TC1 Time
AL1 Low temp.alarm
AH1 High Temp. Alarm
Phase II
SC2 Pit Temps
TC2 Time
AL2 Low temp.alarm
AH2 High Temp. Alarm
Phase III
SC3 Pit Temps
TC3 Time
AL3 Low temp.alarm
AH3 High Temp. Alarm
Phase IV
SC1 Pit Temps
TC1 Time
AL1 Low temp.alarm
AH1 High Temp. Alarm
When you set SC=0, the following Phase will be ignored.
SET2
P1 Meat Temp.
T1 Time for P1, minute
P2 Meat Temp.
T2 Time for P1, minute
P3 Meat Temp.
T3 Time for P1, minute
P4 Meat Temp.
T4 Time for P1, minute
P5 Maximum PIT temp.when meat probe dominates
When turn off/on power, it will continue last mode. Say if you set smoking time for 8 hours, if any power interrupt, when power is back, it will continue.
When you press "AT/M", it will forget auto session.
Reset to default
Turn POWER off for 3 seconds
Press "< " and hold
Turn Power On,88888 appears, then disappear, release