Basic Guideline: the fan will be controlled by pit Temp. first. There are 4 pit temperature stages.
Whenever the meat temperature reachs to P1, the Meat temperature will take over control of fan.
There are 4 meat temperature stages.
When meat temperature controlls the fan, the pit temperature is limited under P5, this way it avoids over burning meat


Summary:

	Working source DC 12V, 2A 
	probes:PT100,  temperature range 0-200C
	Temperature range -50 to 400C for controller, 
	Output: PID 0 to 12V,  or simple on/off
Control Panel:	
NO	Letter		  Description
1		PV1 			Pit Temp	Measured Data
2		SV1				Pit Temp Set Data
3		PV2				Meat Temp	Measured Data
4		SV2				Meat Temp Set Data
5		BATT			Low Battery Voltage
6		OUT		    	Output Indicate
7		ALM1/ALM2		High/Low temperature Alarm	
8		AUTO			Automatic Mode
9		MAN		    	Manual Mode
10		SET1			to set Pit Temp
11		< /BEEP			move left or alarm sound On/Off
12		-				reduce
13		+				increase
14		SET2			To set Meat Temp
15		AT/M			change between automatic/manual
Setting temp. 
Press "SET1", PV1 window will show "SC ,TC,AL,AH,", press "< +-" to set data in SV Window.
Press "SET2" to save above changes
Setting temp. 
Press "SET2", PV2 window will show "P1,T1,P2,T2,P3,t3,P4,T4,P5", press "< +-" to set data in SV Window.
Press "SET1" to save above changes
Setting Parameter£º	
Pres "SET1" and hold for 3 seconds till appearing " F-C", press "SET1", it will show Hdc. Set data accordingly,. Press "SET2" to save	
Setting Maximum Fan Speed (HDC) in %. 
Setting Mimimum Fan Speed(UDC) 
Press "SET1" for 9 seconds, till appearing "P", press "SET1" a few times will appear "Udc", press "+" or "-" till motor starts to run, press "SET2" to save

P		Default 30
I		Default 240
D		Default 60
Udc	Minimum Speed of blower				Default 0, you must set Udc to avoid burning fan
F-C		0=C 1=F	                        Default 0
HdC		Maximum Speed of Blower         Default 100%


Phase I
SC1		Pit Temps      					
TC1	    Time 	
AL1		Low temp.alarm						
AH1		High Temp. Alarm
Phase II
SC2		Pit Temps      					
TC2	    Time 	
AL2		Low temp.alarm						
AH2		High Temp. Alarm
			
Phase III
SC3  	Pit Temps      					
TC3    Time 	
AL3	    Low temp.alarm						
AH3		High Temp. Alarm
Phase IV
SC1		Pit Temps      					
TC1	    Time 	
AL1		Low temp.alarm						
AH1		High Temp. Alarm

When you set SC=0, the following Phase will be ignored.

SET2
P1	Meat Temp.
T1	Time for P1, minute	
P2	Meat Temp.
T2	Time for P1, minute
P3	Meat Temp.
T3	Time for P1, minute
P4	Meat Temp.
T4	Time for P1, minute			 
P5  Maximum PIT temp.when meat probe dominates

When turn off/on power, it will continue last mode. Say if you set smoking time for 8 hours, if any power interrupt, when power is back, it will continue.
When you press "AT/M", it will forget auto session.
	
	
Reset to default
Turn POWER off for 3 seconds
Press "< " and hold
Turn Power On,88888 appears, then disappear, release